7,186 research outputs found

    A circumferentially flanged tibial tray minimizes bone-tray shear micromotion

    Get PDF
    Aseptic loosening of the tibial component is the major complication of total knee arthroplasty. There is an association between early excessive shear micromotion between the bone and the tray of the tibial component and late aseptic loosening. Using non-linear finite element analysis, whether a tibial tray with a circumferentially flanged rim and a mating cut in the proximal tibia could minimize bone-tray shear micromotion was considered. fifteen competing tray designs with various degrees of flange curvature were assessed with the aim of minimizing bone-tray shear micromotion. A trade-off was found between reducing micromotion and increasing peripheral cancellous bone stresses. It was found that, within the limitations of the study, there was a theoretical design that could virtually eliminate micromotion due to axial loads, with minimal bone removal and without the use of screws or pegs

    Copula mixed-membership stochastic block model

    Full text link
    The Mixed-Membership Stochastic Blockmodels (MMSB) is a popular framework for modelling social relationships by fully exploiting each individual node's participation (or membership) in a social network. Despite its powerful representations, MMSB assumes that the membership indicators of each pair of nodes (i.e., people) are distributed independently. However, such an assumption often does not hold in real-life social networks, in which certain known groups of people may correlate with each other in terms of factors such as their membership categories. To expand MMSB's ability to model such dependent relationships, a new framework - a Copula Mixed-Membership Stochastic Blockmodel - is introduced in this paper for modeling intra-group correlations, namely an individual Copula function jointly models the membership pairs of those nodes within the group of interest. This framework enables various Copula functions to be used on demand, while maintaining the membership indicator's marginal distribution needed for modelling membership indicators with other nodes outside of the group of interest. Sampling algorithms for both the finite and infinite number of groups are also detailed. Our experimental results show its superior performance in capturing group interactions when compared with the baseline models on both synthetic and real world datasets

    Regularised semi-parametric composite likelihood intensity modelling of a Swedish spatial ambulance call point pattern

    Get PDF
    Motivated by the development of optimal dispatching strategies for prehospital resources, we model the spatial distribution of ambulance call events in the Swedish municipality SkellefteĆ„ during 2014ā€“2018 in order to identify important spatial covariates and discern hotspot regions. Our large-scale multivariate data point pattern of call events consists of spatial locations and marks containing the associated priority levels and sex labels. The covariates used are related to road network coverage, population density, and socio-economic status. For each marginal point pattern, we model the associated intensity function by means of a log-linear function of the covariates and their interaction terms, in combination with lasso-like elastic-net regularized composite/Poisson process likelihood estimation. This enables variable selection and collinearity adjustment as well as reduction of variance inflation from overfitting and bias from underfitting. To incorporate mobility adjustment, reflecting peopleā€™s movement patterns, we also include a nonparametric (kernel) intensity estimate as an additional covariate. The kernel intensity estimation performed here exploits a new heuristic bandwidth selection algorithm. We discover that hotspot regions occur along dense parts of the road network. A mean absolute error evaluation of the fitted model indicates that it is suitable for designing prehospital resource dispatching strategies. Supplementary materials accompanying this paper appear online

    Notes on the use and interpretation of radiostereometric analysis

    Get PDF
    ABSTRACT With increasing numbers of research groups carrying out radiostereometric analysis (RSA), it is important to reach a consensus on how the main aspects of the technique should be carried out and how the results should be presented in an appropriate and consistent way

    Fixation of a double-coated titanium-hydroxyapatite focal knee resurfacing implant A 12-month study in sheep

    Get PDF
    SummaryObjectiveFocal cartilage lesions according to International Cartilage Repair Society (ICRS) grade 3ā€“4 in the medial femoral condyle may progress to osteoarthritis. When treating such focal lesions with metallic implants a sound fixation to the underlying bone is mandatory. We developed a monobloc unipolar cobalt-chrome (Co-Cr) implant with a double coating; first a layer of commercially pure titanium (c.p.Ti) on top of which a layer of hydroxyapatite (HA) was applied. We hypothesised that such a double coating would provide long-lasting and adequate osseointegration.Design (materials and methods)Unilateral medial femoral condyles of 10 sheep were operated. The implants were inserted in the weight-bearing surface and immediate weight-bearing was allowed. Euthanasia was performed at 6 (three animals) or 12 months (six animals). Osseointegration was analysed with micro-computer tomography (CT), light microscopy and histomorphometric analyses using backscatter scanning electron microscopy (B-SEM) technique.ResultsAt 6 months one specimen out of three showed small osteolytic areas at the hat and at 12 months two specimens out of six showed small osteolytic areas at the hat, no osteolytical areas were seen around the peg at any time point. At both time points, a high total bone-to-implant contact was measured with a mean (95% confidence interval ā€“ CI) of 90.6 (79ā€“102) at 6 months and 92.3 (89ā€“95) at 12 months, respectively.ConclusionsA double coating (TiĀ +Ā HA) of a focal knee resurfacing Co-Cr implant was presented in a sheep animal model. A firm and consistent bond to bone under weight-bearing conditions was shown up to 1 year

    Les Houches Guidebook to Monte Carlo Generators for Hadron Collider Physics

    Full text link
    Recently the collider physics community has seen significant advances in the formalisms and implementations of event generators. This review is a primer of the methods commonly used for the simulation of high energy physics events at particle colliders. We provide brief descriptions, references, and links to the specific computer codes which implement the methods. The aim is to provide an overview of the available tools, allowing the reader to ascertain which tool is best for a particular application, but also making clear the limitations of each tool.Comment: 49 pages Latex. Compiled by the Working Group on Quantum ChromoDynamics and the Standard Model for the Workshop ``Physics at TeV Colliders'', Les Houches, France, May 2003. To appear in the proceeding

    Once-weekly oral medication with alendronate does not prevent migration of knee prostheses: A double-blind randomized RSA study

    Get PDF
    Background and purpose Early migration of joint replacements is an effect of poor fixation and can predict late loosening. By reducing the bone resorption after implantation of a joint replacement, it should be possible to enhance the initial fixation of the implant. We studied the effect of once-weekly treatment with alendronate after knee replacement

    Studies of the decays D^0 \rightarrow K_S^0K^-\pi^+ and D^0 \rightarrow K_S^0K^+\pi^-

    Full text link
    The first measurements of the coherence factor R_{K_S^0K\pi} and the average strong--phase difference \delta^{K_S^0K\pi} in D^0 \to K_S^0 K^\mp\pi^\pm decays are reported. These parameters can be used to improve the determination of the unitary triangle angle \gamma\ in B^- \rightarrow D~Kāˆ’\widetilde{D}K^- decays, where D~\widetilde{D} is either a D^0 or a D^0-bar meson decaying to the same final state, and also in studies of charm mixing. The measurements of the coherence factor and strong-phase difference are made using quantum-correlated, fully-reconstructed D^0D^0-bar pairs produced in e^+e^- collisions at the \psi(3770) resonance. The measured values are R_{K_S^0K\pi} = 0.70 \pm 0.08 and \delta^{K_S^0K\pi} = (0.1 \pm 15.7)āˆ˜^\circ for an unrestricted kinematic region and R_{K*K} = 0.94 \pm 0.12 and \delta^{K*K} = (-16.6 \pm 18.4)āˆ˜^\circ for a region where the combined K_S^0 \pi^\pm invariant mass is within 100 MeV/c^2 of the K^{*}(892)^\pm mass. These results indicate a significant level of coherence in the decay. In addition, isobar models are presented for the two decays, which show the dominance of the K^*(892)^\pm resonance. The branching ratio {B}(D^0 \rightarrow K_S^0K^+\pi^-)/{B}(D^0 \rightarrow K_S^0K^-\pi^+) is determined to be 0.592 \pm 0.044 (stat.) \pm 0.018 (syst.), which is more precise than previous measurements.Comment: 38 pages. Version 3 updated to include the erratum information. Errors corrected in Eqs (25), (26), 28). Fit results updated accordingly, and external inputs updated to latest best known values. Typo corrected in Eq(3)- no other consequence

    Observation of the Dalitz Decay Dsāˆ—+ā†’Ds+e+eāˆ’D_{s}^{*+} \to D_{s}^{+} e^{+} e^{-}

    Full text link
    Using 586 pbāˆ’1\textrm{pb}^{-1} of e+eāˆ’e^{+}e^{-} collision data acquired at s=4.170\sqrt{s}=4.170 GeV with the CLEO-c detector at the Cornell Electron Storage Ring, we report the first observation of Dsāˆ—+ā†’Ds+e+eāˆ’D_{s}^{*+} \to D_{s}^{+} e^{+} e^{-} with a significance of 5.3Ļƒ5.3 \sigma. The ratio of branching fractions \calB(D_{s}^{*+} \to D_{s}^{+} e^{+} e^{-}) / \calB(D_{s}^{*+} \to D_{s}^{+} \gamma) is measured to be [0.72āˆ’0.13+0.15(stat)Ā±0.10(syst)][ 0.72^{+0.15}_{-0.13} (\textrm{stat}) \pm 0.10 (\textrm{syst})]%, which is consistent with theoretical expectations
    • ā€¦
    corecore